Triangle Tube Prestige Boiler Problems, Solutions

Jan 04, 2012 · (1) I have a Solo 110 that makes a horn-like sound just after firing, goes away after about 15 seconds as boiler moves to "high fire". (2) Also, I smell raw gas coming from the intake elbow that connects to the venturi when in standby.

Get Price

How do you light the pilot light on a Baxi boiler?

Jun 06, 2020 · How do you light the pilot light on a Baxi boiler? To light the pilot: Looking through the pilot viewing window press the gas control knob fully inwards and hold. Press in igniter button and release. Repeat until pilot ignites. Continue to hold in gas control knob for approximately 15 seconds and then release. Click to see full answer.

Get Price

How to check ignition on the Baxi Duo-tec & Baxi Platinum

Expert Trainer Dave Driver demonstrates a helpful check you can make to prove ignition on the Baxi Duo-tec and Baxi Platinum boilers even when E133 is displa

Get Price

Solo Boiler Igniter | Winsupply

TRIANGLE TUBE - 1653PTRKIT313, PTRKIT313, Ignitor for Solo 60-399, PE110 Boilers

Get Price

Single Prong Igniter Kit for SL 10-85 G3, SL 14-115 G3, SL

IBC - 0277P340, P-340, Single Prong Igniter Kit for SL 10-85 G3, SL 14-115 G3, SL 20-160 G3, SL 26-260 G3, SL 40-399 G3 Residential Condensing Boilers

Get Price

Triangle Tube boiler problems | Terry Love Plumbing Advice

Aug 09, 2019 · When it came on it would go whoomph. I finally called the company that I bought the boiler from and asked them to come and look at it. They said that the igniter was defective and was causing a delayed ignition. I later learned that these are "Micro explosions". They charged me $277.00 to replace the igniter. It lasted for about a week.

Get Price

Baxi Boiler Problems, Repair Advice & How to Fix

Baxi boiler warranty. The majority of Baxi boilers come with anywhere between 2-7 years of warranty as standard. Use our complete guide to Baxi warranties so that you know exactly what to expect. To keep a boiler warranty valid, a service will need to be carried out annually, this means that you'll need to arrange for a Baxi boiler service for every year of the warranty.

Get Price

Igniter Gasket Kit for Gas-Fired Hot Water Boiler | Winsupply

A. O. SMITH - 1660100110748, 100110748, Ignitor Gasket Kit for Gas-Fired Hot Water Boiler

Get Price

TT Prestige Solo 110 Igniter problem SOLVED | Terry Love

Jan 24, 2018 · There are many types of ignition problems but I discovered the solution to this particular igniter problem when troubleshooting a growling or horn like noise coming from the Prestige 110 boiler. The solution to the noise is posted as a separate thread titled: TT Prestige Solo 110 Growling/Horn noise SOLVED.

Get Price

Triangle Tube Prestige Solo Boiler Parts - Parts4Heating.com

Solo 250. The Triangle Tube Prestige Solo is a wall-hung, condensing boiler featuring a stainless steel heat exchanger and 90%+ AFUE efficiency. Features include a zero-clearance to combustables installation, standard PVC venting, simple bottom-of-enclosure piping, controls for the easy addition of an external indirect-fired water heater, and freeze-protection operation …

Get Price

Triangle Solo — Heating Help: The Wall

Triangle Tube prestige solo boilers when there is a call for domestic hot water the boiler delivers 180*F water to the indirect. Is the boiler on high fire for all domestic hot water calls? if you run out of hot water install a 80 gallon electric water heater and circulator with the smart 60 …

Get Price

How to reset a Baxi boiler | Baxi

The process of resetting your boiler is the same regardless of the fascia display. To reset the boiler, turn the selector switch to the R (Reset) position. Hold for at least 5 seconds and release. The fault code will be replaced with the boiler's current temperature. At this point on a neon indicator boiler model, the flame failure light will

Get Price

Winsupplyinc.com

Navien NHB condensing boilers As the leader in condensing technology, Navien has already reinvented the water heating industry with the award-winning NPE tankless water heaters and the NCB combi-boilers. The new NHB boiler series is the next in line of innovations from Navien. All NHB boilers have Navien's advanced burner

Get Price

Prestige Solo TriMax 155000 BTU Condensing - Winsupply

TRIANGLE TUBE - 1653PA155, PA155, The flagship line of premium condensing fire tube gas boilers has been updated, adding 2 new models (155 and 299), and replacing the 60 with an 80. The prestige boiler continues to feature the uniquely designed stainless steel heat exchanger and boasts 95% efficiency across the entire range. The prestige has the capability to modulate with …

Get Price

Condensing Solo Boilers | Triangle Tube

Prestige Solo. High efficiency wall mounted gas condensing boiler. 95% energy efficient. Available in a broad range from 80 to 399 MBTU. NEW – Market-leading Warranty Program with up to 6-Years Parts, 3-Years Labor Allowance and 10-year Primary Heat Exchanger Warranty. 439 Stainless Steel Fire Tube Heat Exchanger. Turndown ratios up to 5.5:1.

Get Price

Triangle Tube Prestige Solo Boiler Parts - Parts4Heating.com

The Triangle Tube Prestige Solo is a wall-hung, condensing boiler featuring a stainless steel heat exchanger and 90%+ AFUE efficiency. Features include a zero-clearance to combustables installation, standard PVC venting, simple bottom-of-enclosure piping, controls for the easy addition of an external indirect-fired water heater, and freeze-protection operation whereby the …

Get Price

Prestige Solo 60 on propane - ignition issues — Heating

Basically, the boiler will ignite fine if he turns the gas throttle screw full on, but then the combustion numbers are all out of whack. Once he dials in the combustion within spec, the boiler maintains a steady flame while lit, but will no longer relight. …

Get Price

Baxi Heat Solo 3 PF Installation and - Baxi Boilers | Baxi

Baxi Solo 3 70 PF G.C.No. 41 075 08 Baxi Solo 3 80 PF G.C.No. 41 075 09 Baxi is a BS-EN ISO 9001 Accredited Company The boiler meets requirements of Statutory Instrument "The Boiler (Efficiency) Regulations 1993 No 3083" and is deemed to meet the requirements of Directive 92/42/EEC on the efficiency requirements for new hot water boilers

Get Price

Baxi Solo 2 PF and Baxi Solo 3 PF Boiler Faults, Problems

Nov 01, 2020 · This boiler fault could occur in any of the Baxi Solo 2 PF or Solo 3 PF or Solo 3 PFL boilers. Ignition electrodes on a Baxi Solo PF boiler. This spark jumps between the small rod and the C shaped metal pilot hood. Probably the commonest cause of a Solo PF boiler not going from pilot to main burner is a solenoid failure on the gas valve.

Get Price

Home - TriangleTubeParts.com

Prestige Trimax Control Module, Solo 60, 110, 175, Excellance $329.00 $320.78 MFG#: PTRKIT205 To ensure compatibility - Please enter your boiler's model# and serial# below

Get Price

Plumbing Valves - SupplyHouse.com

Boiler drains remove water and any accumulated sediment from boilers and wye strainers (Y-strainers) remove solids and debris from steam, gas, and hydronic systems. Your One and Only Stop As the top valve supply online, we stock valves from leading manufacturers in the plumbing and heating industries, perfectly suited for any system.

Get Price

Triangle Tube PSRKIT15 Prestige Igniter with Gasket

Make sure this fits by entering your model number. Ignitor with gasket for: Prestige solo 60, 110, 175, 250, 399 boilers. Prestige excellence 110 boilers. Package Dimensions: 7.2" L x 16.1" W x 16.2" H. › See more product details. New & Used (4) from $54.78 & FREE Shipping.

Get Price

Crown Boiler Parts - Parts4Heating.com

Crown Boiler 35-4700 Pilot Assy, Spark Natural Gas 1/8 in. X 30 in. PILOT TUBING Crown Boiler 150502 Burner, 1" W/Pilot Bkt (Q350 Pilot)

Get Price

STEAM BOILER OPERATING AND MAINTENANCE MANUAL

Operation of the steam boiler should be conducted by a mechanical installation and electricity technician. Defective armatures or control elements must be replaced by identical parts.

Get Price

Triangle Tube Solo 110 Boiler Parts - Parts4Heating.com

Triangle Tube Solo 110 Boiler Parts - Parts4Heating.com Triangle Tube PSRKIT15 Igniter w/Gasket Triangle Tube PGRKIT20 LWCO Device Triangle Tube Prestige Solo PSRKIT55 Blower Kit, Solo 60 and 110 Grundfos UPS 15-58 Circulator …

Get Price

Solo Boiler Igniter with Gasket - Triangle Tube Parts

Solo Boiler Igniter with Gasket. Solo Boiler Igniter with Gasket. $52.07 Reg. Price $62.00 You Save $9.93. in stock. Ignitor with Gasket for: Prestige Solo 60, 110, 175, 250, 399 Boilers, Prestige Excellence 110 Boilers. Please contact us for more information.

Get Price

Triangle Tube Prestige Solo Boiler ignition issue - any

Aug 14, 2016 · The tech came out and said i needed a new igniter/ ignition cable, however, he could not remove the old one because he couldn't get the 2 screws out because of rust. This is after 4 years of use. Since he couldn't get the igniter out, the tech proposed replacing the entire top plate to the boiler which seems very unnecessary. I have lost faith

Get Price

Prestige Trimax 175 Ignition Kit - Installation Instructions

Table 1 - PT Ignition Kit Numbers 1.2. Purpose This kit (see Fig. 3 for details) replaces the existing TriMax control module, the igniter and wiring, the internal venting tube and the heat exchanger insulation. 1.3. Initial tasks Confirm the replacement kit is appropriate for the boiler to be worked on (see Table 1).

Get Price

baxi solo 15 he wont ignite | DIYnot Forums

Sep 05, 2013 · Country: hi, got a baxi solo 15 he. I had a gas leak on my cooker hob. Gas man turned the mains off. I then isolated the hob and turned the mains gas back on. Now the boiler won't ignite. Power light is on but the red 'lockout' light is on. I've pressed the reset button (lots of times) in case there is an air lock but the lockout light keeps

Get Price

Hot Surface Igniter for Model M100(V), TI100 - Winsupply

NTI - NTI82708, 82708, Hot Surface Igniter for Model M100(V), TI100 to TI400 Trinity Series Gas Boiler

Get Price

Help Videos | Triangle Tube

Product Recall Repair Video – If your boiler is subject to the recall, a professional must get approval from Triangle Tube prior to performing the repair. Contact our toll-free number 877-574-5036 in the US or in Canada. Please go to the Product Recall page on our website to identify if your boiler is affected. Product Recall Info.

Get Price

Gas Specification Sheet Hot Water Boiler

Dimensions NHB Series Hot Water Boilers Condensing Gas Specification Sheet Hot Water Boiler Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 .Navien.com Rev. 12/14 Specifications Model Number1 Heating Input, MBH Heating Capacity2, MBH Net AHRI Rating, Water3, MBH

Get Price

Baxi Solo 2 No ignition - YouTube

Attended to boiler which was sparking but not igniting. Upon inspection it was found that it had never been serviced. All necessary checks and adjustments w

Get Price

What Are The Major Steam Boiler Components? – Getabec

Aug 28, 2021 · Condensate pumps: In a steam boiler, the condensate pumps push the condensate water that was converted from steam after its heat energy was utilized at the required place and help it reach back to the boiler so that it can be reheated to generate steam. Exhaust Stack: The exhaust stack is used to remove the flue gases that are produced due to the …

Get Price

Hydronics | Hydronic Boilers | Thos. Somerville Co.

80, 105 Sizes Ultra Gas Boiler Model (1) Suitable For Use With 80%2C+105+Sizes+Ultra+Gas+Boiler+Model 80, 105 Sizes Ultra Gas Boiler Model. 88 Series Boiler (5) Suitable For Use With 88+Series+Boiler 88 Series Boiler. 299 Boiler Model (1) Suitable For Use With 299+Boiler+Model 299 Boiler Model.

Get Price

Changing The Boiler Igniter. - YouTube

After cleaning the burners the boiler ran for maybe 2 hours then started blinking a 4 code which is an igniter failure.OH goody .I should have changed it any

Get Price

Triangle Tube PARKIT132 Igniter/Ignitor for Prestige Solo

Triangle Tube PARKIT132 Igniter/Ignitor for Prestige Solo PA 299 / PA 399 Hot Water Boiler and Water Heaters. Repairs Model: Triangle Tube Prestige Solo PA 299 Triangle Tube Prestige Solo PA 399 Product Description: Igniter for Models PA 299 / PA 399 Dimensions: Length of Igniter Probes from Plate: 3-3/8" Length of Ins

Get Price

Alabama Department Of Labor, Boiler and Pressure Vessel Safety

Today, unfortunately unsafe boilers and pressure vessels can, and do, suffer catastrophic failures. The injuries and deaths attributed to boilers and pressure vessels today, although few by comparison, do happen. Permits must also be obtained to install boilers and pressure vessels. This includes Water Heaters over 200,000 btu or over 120

Get Price

Failed ignition on triangle tube pt 110 — Heating Help

April 2014. Combustion, igniter, or board. First have someone check the boiler with combustion analyzer and make sure it is within specs. If that is ok, change igniter with "short" porcelain as reccomended by TT. They've been having problems with …

Get Price

Prestige Trimax 60-110 Ignition Kit - Installation

Ignition Kit - Installation Instructions 1.1. Applicability Prestige boilers with "PT"-prefixed serial number, as indicated on data plate. Kit Part Number Model PTRKIT301 PT 60-110 Table 1 - PT Ignition Kit Numbers 1.2. Purpose This kit (see Fig. 3 for details) replaces the existing TriMax control module, the igniter and wiring, the internal

Get Price

Baxi Solo 2 50 PF - Ignition Problems | PlumbersForums.net

Nov 23, 2011 · Replaced it back & Volla! the result is pilot now switches on in less than 5 ignition clicks & my boiler is back to normal. Have had it running all day yesterday & night without fail. I am now looking to buy a cheap APS for my solo. Cheapest one has come from an ebay contact, £18 inc. delivery. I say that is reasonable for a switch.

Get Price