Shandong Huayuan boiler Co Ltd Others


Shandong Huayuan boiler Co Ltd Others

Shandong Huayuan boiler Co Ltd Others
  • Offshore price : $8,999.00 - $100,000.00
  • Minimum order quantity : 1 set
  • Supply Capacity : 10 units/month
  • Manufacturer/Brand : TOBO BOILER
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA
I need the quotation of for Ton/KW , the fuel is , use for ,My name is , my Email is ,my phone number is , Please Send the detail information for me!

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

Removing back boiler | Screwfix Community Forum

Removing back boiler | Screwfix Community Forum

Get Price

Fitting a Stove to an Open Fire with Existing Back Boiler

Jul 03, 2014 · Hi Folks, I am in the process of purchasing a property that has an open fire with back boiler. A brief chat with the vendor tells me they never got the efficiency out of the back boiler they would have liked, lukewarm rads etc. Afaik it's much more efficient to fit a …

Get Price

New fire for a back boiler — MoneySavingExpert Forum

Aug 11, 2009 · 114 Posts. 5 July 2007 at 4:19PM in In My Home (includes DIY) MoneySaving. Hello all, we have a horrible dated 1980s gas fire in the new home we've moved into. It's got a back boiler behind it and when we had the gas check carried out on the house before we moved in we were advised we couldn't just buy a new gas fire to replace it as we needed

Get Price

Can you still get a Back Boiler for an open fire

Mar 04, 2011 · 535 Posts. 29 January 2007 at 9:00PM. hi I got a open fire back boiler installed last year so you can still get them,we got ours from aerocrete on shore road around the whitewell area around the £300 I think but try them anyway,ours will also heat up to 7 rads as well. 0. 30 January 2007 at 10:32PM.

Get Price

disconnect a back boiler | PlumbersForums.net

Mar 10, 2013 · ian260281. Mar 10, 2013. #1. hello - I have just bought my first house and wish to drain and disconnect the pipes feeding the backboiler as the chimney breast has recently craked and I need to fit a log burner, therefore digging out the backboiler. there is a drain tap next to the fire breast. there is a pipe feeding and returning the HW tank.

Get Price

Permanent live to a boiler | Electricians Forums

Mar 06, 2009 · Assume that the main supply is upstairs in the airing cupboard together with the clock,vave(s) etc. There is just a t/e running down to the boiler. Clever heating firm come along and fit an Icos boiler that needs a perm live or a back boiler that has lights in the front or electronic ign for the gas fire.

Get Price

Replace Baxi Firefront | Screwfix Community Forum

Oct 13, 2008 · We have an old Baxi 552 back boiler with a nasty looking fire front attached. We want to replace the fire front with something nicer looking. I like the simplicity of the boiler and consider the "savings" made by replacing with a new condensing boiler to be a false economy as I can imagine any new boiler fitted not to last as long as our Baxi.

Get Price

Sierra Plumbing And Heating - What pipe fitting for shower

Oct 18, 2021 · Removing old Baxi Back Boiler, 1930's, Asbestos? | DIYnot from .diynot.com Is the trusted solar and hvac company of sacramento, ca. Yelp is a fun and easy way to find, recommend and talk about what's great . Full service commercial plumbing and …

Get Price

Sierra Plumbing And Heating - What pipe fitting for shower

Nov 10, 2018 · Pilot Light On Back Boiler Diynot Forums Baxi Boiler How To Relight A How To Use Baxi Duotec Condensing Combi Boiler You How To Relight Your Pilot Boiler Sse You Baxi Boiler Fault Mp4 You Baxi Solo 3 50 Pf Intermittent Burner Diynot Forums Baxi Duo Tec 28 Boiler You Baxi Boilers Manuals Images E993 Com

Get Price

Cost of replacing back boiler with Combi

Mar 14, 2015 · 598 Posts. 14 March 2015 at 6:13PM. Our Baxi back boiler died last week, and we are having it replaced by a new conventional condensing boiler (not combi) in the airing cupboard upstairs. That is costing us £3500, including boiler, new hot water tank, new immersion for backup, new pump and thermostat.

Get Price

If anyone wants advice on gas/central heating/boilers

Oct 15, 2021 · They all want to fit baxi boilers. They will not let me know what radiators they will use and the model number of the boiler. This was not aggressively sought but asked when on site visit during overall conversation over work. What is a surprise is most come and quote £3,500 roughly then go away and come back with around £5,000.

Get Price

Baxi System Boiler Wiring Diagram - Wiring Diagram

Removing back boiler | Screwfix Community Forum

Get Price

Removing back boiler | Screwfix Community Forum

Jul 07, 2007 · When you've solved that, you need to remove the back boiler by disconecting the pipework to it, either at the back boiler or at the cylinder. If it does have to come out that's straightforward but mucky (sooty - no sweep). You should find a drain cock near the b/boiler.I'm assuming the back boiler will be from an old coal fire.

Get Price

Fitting a back boiler | Irishkop.com

Mar 09, 2011 · Fitting a back boiler really depends how close you are to the heating pipes in the house. If the house is 2 storey or bungalow you also need lots of room behind the fire a lot of new houses only have room for the fire back if this is the case you will need to make the opening bigger or fit a smaller fireplace.

Get Price

Back boiler and oil heating - the Irish consumer forum

Nov 09, 2014 · Oil boiler, stove with boiler. Separate control of 2 zones. When using oil or stove. Control of heating only water on oil. Solid fuel boiler will always heat water. The stove/ back boiler must be piped to your cylinder with no obstruction to gravity flow with inch copper piping. Best if the run is not too long.

Get Price

Fitting a Stove to an Open Fire with Existing Back Boiler

Jul 03, 2014 · Hi Folks, I am in the process of purchasing a property that has an open fire with back boiler. A brief chat with the vendor tells me they never got the efficiency out of the back boiler they would have liked, lukewarm rads etc. Afaik it's much more efficient to fit a …

Get Price

Difficult Door Threshold/Laminate Flooring DIYnot Forums

Difficult Door Threshold/Laminate Flooring DIYnot Forums. How to Install Laminate Flooring for beginners . · The boiler is heating the water, then the water leaving the boiler gets too hot so the boiler shuts down until water leaving the boiler is cool again, and then cycles. One solution is to turn DOWN the required temperature of the water.

Get Price

How To Relight Pilot Light On Baxi Solo Boiler | Shelly

Mar 09, 2011 · Fitting a back boiler really depends how close you are to the heating pipes in the house. If the house is 2 storey or bungalow you also need lots of room behind the fire a lot of new houses only have room for the fire back if this is the case you will need to make the opening bigger or fit a smaller fireplace.

Get Price

New Gas Fire for back boiler | Screwfix Community Forum

Feb 02, 2018 · Dave does Gas Screwfix Select. Unless you can get the specific fire for the model of BBU you have then no, the two parts fire and boiler link to make a combined flue system you cannot use the boiler without the fire in situ. You can however de-commission the boiler and leave it in place and continue using the fire.

Get Price

Is it possible to fit a back boiler to an existing fire

May 19, 2012 · Back boiler must always have an unrestricted flow and return (primary circuit) to cylinder or buffer tank. Back boiler must always be vented unrestricted. Safety valves are always fitted to any heat producing appliance. They are not to be used to side step any other safety features inc expansion vent pipe.

Get Price

Baxi Boiler - any good — Digital Spy

Jul 14, 2010 · The Baxi Duo-Tec is an excellent boiler. Try googling DIYNot, MSE or the Screwfix forum for some impartial advice. Never had a callback on a single one of them Do NOT buy the W-B junior range, they are the cheap contract model, the CDI is more expensive but far superior. But, hey, Seacam is the acknowledged and undisputed expert here

Get Price

Drilling and fitting a back boiler - Forums - Canal World

Feb 10, 2015 · On the back of my Morso Squirrel there were three holes marked. You need to cut two holes, top right and bottom left as you look at the back of the stove. 1. Purchase back boiler and await excitedly for delivery. 2. Remove the flue from the stove. It might be possible to remove the flue without removing the roof collar. 3.

Get Price

Boiler & Heating FAQ's | Baxi

Back boilers (also known as back boiler units or BBUs) became popular in 1966 with the launch of the original Baxi Bermuda. A back boiler is a small, compact boiler fitted at the back of an open fireplace hearth. It sits behind a gas fire and provides hot water and central heating to …

Get Price

How much to fit a wood burner/ multi fuel stove

I've been told it's 2 days work as the old coal fire and back boiler need removing, though the back boiler is already disconnected plumbing wise. The old fire place ripped out and new hearth

Get Price

Back boiler still kettling after cleaning | PlumbersForums.net

Oct 24, 2017 · Messages. 7. Oct 23, 2017. #1. I put some cleaning fluid through my system about 6 weeks ago and drained down at the weekend I ran the heating until the water was clear but after filling I still have kettling when only HW is running. As far as I'm aware the HW is heated by gravity as I cannot see a valve only the pump.

Get Price

Fire fitting possible with this? | Page 2 | DIYnot Forums

1 day ago · DIYnot Forums. Home Forums > How to > Plumbing and Central Heating > Normally it is because there was a Back Boiler - but that would entail chair brick removal. My assumption would be that there was a BBU, hence the liner. Then someone removed the BBU to fit an angled inset tray, so had to fit a chair brick. Which would mean the liner is

Get Price

Baxi Boiler Problems, Repair Advice & How to Fix

Baxi boiler warranty. The majority of Baxi boilers come with anywhere between 2-7 years of warranty as standard. Use our complete guide to Baxi warranties so that you know exactly what to expect. To keep a boiler warranty valid, a service will need to be carried out annually, this means that you'll need to arrange for a Baxi boiler service for every year of the warranty.

Get Price

Relighting Pilot Light On Baxi Boiler | Shelly Lighting

BAXI bermuda back boiler - time to upgrade ? | DIYnot Forums

Get Price

Back boiler for double sided stove | PlumbersForums.net

Mar 19, 2013 · Solid fuel stove boilers wrap around the inside of the stove taking heat from the two sides and the back of the stove, the tappings (pipe connections) are on the back of the stove, this is not really possible to achieve with a double sided stove. Taking tappings from the side of the stove could in my opinion cause a major safety issue as the

Get Price

Boiler Gas Valve Problems And Faults - Heating | Gas

Across many online forums, you'll see various horror stories, where homeowners have replaced the gas valve, and even the PCB, only to find that the problem hasn't been fixed. A specialist boiler repair company will be able to test the valve and monitor it after every adjustment to make sure that this is the problem.

Get Price

So Much For Compassion

14 hours ago · I worked for a construction company. Our heating engineer was supposed to go to a property regarding fitting a new boiler, but his mother passed away. I called the customer. Me: ", I'm afraid won't be able to come fit your boiler due to a family bereavement."

Get Price

Back boiler, old controls - MoneySavingExpert Forum

Apr 22, 2018 · At a guess, you have a Baxi Bermuda back boiler running a gravity fed heating system - Whilst these boilers are not as efficient as a modern condensing boiler, they are simple and fairly inexpensive to service & repair. I also have one of these systems, and the return on investment to replace it means I won't see any savings for at least 15 years.

Get Price

Pilot Light On Baxi Boiler Keeps Going Out

Jul 07, 2007 · When you've solved that, you need to remove the back boiler by disconecting the pipework to it, either at the back boiler or at the cylinder. If it does have to come out that's straightforward but mucky (sooty - no sweep). You should find a drain cock near the b/boiler.I'm assuming the back boiler will be from an old coal fire.

Get Price

Back boiler condemned because of flue - Page 1 - Homes

Apr 11, 2019 · We had our back boiler removed and combi moved to the loft came in at £2,500, the boiler was about £1,200 on its own. We ended up having all the copper pulled out and replaced and new rads

Get Price

Fitting a Back Boiler To A Wood Burner | PlumbersForums.net

Oct 20, 2020 · Oct 20, 2020. #3. Alan Wright said: I fitted the back boiler today myself and it was very straightforward. One of my new radiator flow booster takes the heat away and now the wood burner heats the radiator in the entrance hall but when I turn on the main recirculation pump it takes the hot water to the rest of the house.

Get Price

Compare Gas Boiler Prices, Efficiency & Warranty

VIEW. Alpha E-TEC 33kW Combi Gas Boiler. VIEW. 29.7 kw. 93%. 7 years. £815. VIEW. Alpha EVOKE 28kW Combi Gas Boiler.

Get Price

To remove back boiler or not - the Irish consumer forum

Oct 08, 2008 · 877. 29 Sep 2008. #4. Get rid of the back boiler, not because of the gas heating but because it is an awfully bad system. With a bb, most of the heat from the fire goes up the chimney, and a bb will not heat your water all that well. I am a country lad and like an open fire.

Get Price

Fire fitting possible with this? | Page 2 | DIYnot Forums

1 day ago · DIYnot Forums. Home Forums > How to > Plumbing and Central Heating > Normally it is because there was a Back Boiler - but that would entail chair brick removal. My assumption would be that there was a BBU, hence the liner. Then someone removed the BBU to fit an angled inset tray, so had to fit a chair brick. Which would mean the liner is

Get Price

Pilot Light On Baxi Boiler Keeps Going Out

Nov 01, 2018 · Pilot Light On Baxi Boiler Keeps Going Out. Gas boiler pilot light not staying on baxi boiler flame out 2 you pilot light on back boiler diynot forums baxi boiler flame out problen 1. How To Reset Your Boiler When It Locks Out Ovo Energy. Malfunctions Of Gas Boilers Baxi Double Circuit Wall Mounted Boiler Operating Features And Possible.

Get Price

Replace Back Boiler with COmbi | DIY Doctor UK DIY Forums

Dec 19, 2008 · Hi Guys, Looking at replacing an old(10 years ish) back boiler with a new combi boiler in the loft and getting rid of the header tank and other tank. Any one done this and what sort of Savings did you get on heating bills etc? Also a guy I know used all push fit plastic pipes for a house re fit of CH, are they ok to use throughout the house?

Get Price

Back Boiler | Screwfix Community Forum

Jul 05, 2006 · just treat it like any other conventional system,drain down from as low a position as possible, all the downstairs rads will still be full, change valves, refill, vent, remove airlocks, and off you go, no need to touch the boiler at all. tomplum, Jul 4, 2006. #2. Simon J New Member. Thanks Tomplum, fitting the TRV's tomorrow. Simon J, Jul 4, 2006.

Get Price

vaillant boiler pipe diagram vaillant boiler pipe diagram

vaillant boiler pipe diagram 07 Jan. vaillant boiler pipe diagram. Posted at 22:28h in honest amish slick beard wax by euphonious definition. psychology behind shameless Likes.

Get Price

Step-by-step guide to boiler installation - British Gas

Having a new boiler installed is a big, often expensive, decision — and there are lots of considerations. Our step-by-step guide to boiler installation should make things a little clearer for you, so that you can feel confident in what to expect when you take the plunge.

Get Price

Old Back Boiler Help | Screwfix Community Forum

May 08, 2015 · Thx for replys the system was integrated into the existing plumbing and worked fine off an open fire which was also combined with the oil fired central heating,we wanted to fit a boiler stove but were told it would be too expensive to plumb so now we have no heating at all lol i'm assuming that the system is on a kind of loop so by cutting and capping the pipes the loop …

Get Price

back boiler set up - New to Boating? - Canal World - Forums

Jun 15, 2013 · A multifuel back boiler must be run unpressurised as it's an uncontrolled heat source. The main choice is to go for gravity or pumped circulation, or a combined 'best of both' approach. Then it's designing a decent layout which admittedly is a lot easier for fully pumped. A forum search on 'back boiler' will turn up loads of threads with useful

Get Price

back boiler no heating,please help. | DIY Doctor UK DIY Forums

Nov 05, 2008 · According to what you have said in the past, you have a Halstead ace, a Worcester 24i as well as a back boiler. Now you are going to fit a new combi. I do hope there is some logical explanation for this because, this is a DIY forum designed to help householders, and is not here to help cowboy installers pick the brains of experienced tradespeople.

Get Price

Oil Fired Heating with Back Boiler Help | Screwfix

Jan 05, 2018 · The Lines in purple are what I believe are connected the back boiler. Purple triangle has a manual switch we press when the back boiler starts to make boiling noises. (picture of this attached) The green star is my intended location for a new zone valve so we can separate upstairs and downstair heating.

Get Price

How to fit a back boiler | DIYnot Forums

Sep 03, 2019 · Back boilers are very inefficient and I would certainly not be fitting one in a new house. Even in Ireland I would have expected the Building Regs would have had some energy efficiency aspects to be met. A open flued boiler ventilation changes the air many times an hour and seriously increases the running cost compared with a room sealed boiler.

Get Price

Relight Pilot Light Vokera Boiler | Shelly Lighting

Oct 20, 2017 · Baxi system 24 wiring harness diagram heating spare parts combi 80 eco central diagrams megaflo 2 compact 630 fs 401 rs chb internal programmer 105 he honeywell cm927 diynot forums 818 connecting hive to duotec boiler overheating combination with zones 230v switching solo pf 60 earlier appliance 105e query on installing a thermostant how does an s …

Get Price

Coal fire/back boiler removal help | Screwfix Community Forum

Oct 01, 2017 · Simon Millar New Member. I'm looking to remove a coal fire which has a back boiler and has recently been in use. Pipes now disconnected etc but finding it very difficult to even attempt to remove it seems there is a lintel about a meter up from ground but below is all bricks with a small opening for the recent coal fire.

Get Price
Hey, let me help you!